| Анкета |
| Познавате ли себе си?
Да! Винаги зная как ще постъпя
9 гласа (42%)
Вероятно! Правя каквото трябва
3 гласа (14%)
Понякога сам се изненадвам
5 гласа (23%)
Не съм уверен достатъчно
3 гласа (14%)
Въпроса не ме засяга
1 глас (4%)
|
Календар
| << |
Юли 2008 |
>> |
|
>
|
30 |
1 |
2 |
3 |
4 |
5 |
6 |
|
>
|
7 |
8 |
9 |
10 |
11 |
12 |
13 |
|
>
|
14 |
15 |
16 |
17 |
18 |
19 |
20 |
|
>
|
21 |
22 |
23 |
24 |
25 |
26 |
27 |
|
>
|
28 |
29 |
30 |
31 |
1 |
2 |
3 |
|
|
HER-2
IHC Select® Anti-c-erbB-2, prediluted, clone CB11 CHEMICON IHC SELECT RESEARCH PREDILUTED MOUSE ANTI-c-erB-2 MONOCLONAL ANTIBODY CATALOG NUMBER: IHCR2050-6 QUANTITY: 6 mL HOST/ISOTYPE: Mouse IgG1 ALTERNATE NAMES: HER-2; neu CLONE NAME: CB11
SPECIFICITY: Human c-erbB-2 (HER2/neu) protein, internal domain. Specific binding demonstrated by immunoprecipitation of c-erbB-2 oncoprotein from SKBr3 cells.
IMMUNOGEN: Synthetic peptide corresponding to a site on the internal domain of the c-erbB-2 protein. APPLICATIONS: Antibody is prediluted and ready to use for Immunohistochemistry of formalin-fixed, paraffin-embedded tissues.
Pretreatment: Heat Induced Epitope Retrieval (HIER). Recommend Citrate Buffer, pH 6.0 (Cat. No. 21545). No signal was detected without Epitope retrieval.
Incubation: 10 minutes with IHC Select® Detection Kits.
c-erB-2 has been prediluted for use as the primary antibody with Chemicon’s IHC Select® Detection Kits and Protocols (Catalog Nos. DAB050, DET-HP1000, APR050, and DETAPR1000), but other supplier’s IHC detection systems may be used. For optimized protocol details, visit www.chemicon.com and select the protocols link under Cat. No.IHCR2050-6.
SPECIES REACTIVITIES: Reacts with Human. Reactivity with other species has not been confirmed.
PRESENTATION: Liquid diluted in PBS, pH 7.2 with stabilizers, 0.2% Tween 20, and 0.1% ProClin 300 as preservative.
STORAGE/HANDLING: Maintain at 2-8oC . Refer to vial for expiration dating.
For research use only; not for use as a diagnostic.
Important Note: During shipment, small volumes of product will occasionally become entrapped in the seal of the product vial. For
products with volumes of 200 µL or less, we recommend gently tapping the vial on a hard surface or briefly
centrifuging the vial in a tabletop centrifuge to dislodge any liquid in the container’s cap.
|
Връзки по темата
www.chemicon.com
|
| Статистика |
| Всички посещения: |
19339394 |
| Посещенията днес: |
35838 |
| Този месец: |
1168184 |
| Посетителски пик: |
568 |
| Посещенията вчера: |
68588 |
|
|
|
|